a

Linear Actuator Control Units

                                                                                                                                                              

 

Linear Actuator 4 Channel Control Unit  

Operating Instructions

(LA-SYNCON)

8 Channel Synchronization (4 up, 4 down)

RF Remote Control

Momentary and Latching Operation

Dual Fused 12/24 Volt DC Input

                                                        

 

IMPORTANT 

 PLEASE READ THESE INSTRUCTIONS IN FULL PRIOR TO OPERATION

 

 

Wiring 

Input – 2 x 12 volt or 24 volt (10 amp minimum) direct current power sources are required to operate this unit (if the load is less than 7.5 amps, you can piggy-back the two positive and the two negative power input wires together and use only one power source), red wire to positive (+) (indicated by the fused link) and the black wire to negative. If only two channels are required then power should be supplied to the left input side only.

 

Output – The four leads for the actuators are indicated by the four identical weather proof two pin plugs. These are to be wired to the actuators as follows, red to brown and black to blue (remembering that if only two actuators are required then use the plugs on the left hand side of the control box only).

  

Operation

 Momentary - Press and hold button A on the remote control for extension of the actuator. Press and hold button C for the retraction of the actuator. Alternatively, press and hold either up or down on the momentary toggle switch mounted on the face of the control box.

 

Latching - Press button B once only for extension and any other button to pause or stop operation. Press button D once only for retraction and any other button to pause or stop operation.

  

Synchronization

Synchronization is only possible whilst using the momentary functions, either via the toggle switch on the control box or the A and C buttons on the remote control.

The top row of dials controls the speed of extension for channels 1 through to 4. The bottom row of dials controls the speed of retraction for channels 1 through to 4.

                                                                                                                                     

Linear Actuator 2 Channel Control Unit         

Operating Instructions

(LA-REMCON)

2 channel Control Unit

RF Remote Control

Momentary Operation

Fused 12 Volt DC Input

  

IMPORTANT

 PLEASE READ THESE INSTRUCTIONS IN FULL PRIOR TO OPERATION

  

Wiring

Input  - A 12 volt direct current power source providing a minimum of 10 Amps is required to operate this unit, red wire to positive (+) (indicated by fused link) and black wire to negative (-).

Output – The two leads for the actuators are indicated by the two identical weather proof two pin plugs. These are to be wired to the actuators as follows, red to brown and black to blue. Insulated male and female spade connectors are recommended.  

Operation

Press and hold button A on the remote control for extension of the actuator. Press and hold button C for retraction of the actuator.

Alternatively, press and hold either up or down on the momentary toggle switch mounted on the face of the control box.

  

 

 

WARRANTY

Australian Gas Springs (‘AGS’) of 29 Tower Court, Noble Park 3174, Victoria, Australia warrants to the original purchaser that LiftEasy control unit will be free from defects in materials and workmanship under normal use and service for a period of twelve months from the date of original purchase.

This limited warranty is not applicable if the product has been damaged by accident, intention, improper installation, unreasonable or improper use, lack of proper maintenance, unauthorized repairs or modifications, normal wear and tear, or other causes not arising from defects in materials or workmanship and if production identification is not intact.

AGS’ obligation under this warranty is limited to repair of the product at AGS’ premises or replacement of the products at AGS’ option without expense to the original purchaser. Any expenses involved in the removal, reinstallation or transportation of the product are not covered by this warranty. The product must be returned to AGS’ premises at, 29 Tower Court, Noble Park 3174, Victoria, Australia, postage pre-paid, and insured with proof of original purchase including purchase date. If AGS is unable to replace the product and repair is not commercially practical, AGS may at its discretion refund the purchase price, less an amount for depreciation. Products that are replaced or for which a refund is issued become the property of AGS.

This warranty is AGS’ only expressed warranty of these products, no implied warranty including, without limitation, the implied warranties of merchantability and fitness for a particular purpose, shall be extended beyond the warranty period stated above for each product. AGS shall not be liable for any damages, for loss of use of this product, nor for any other incidental or consequential damages, costs, or expenses.

A claim for product damage or loss occurring in transit is the responsibility of the carrier. In the event of such a loss, the purchaser must advise the carrier within 14 days after delivery and secure the carrier’s notation of damage or shortage in the freight bill. AGS suggests the purchaser file a claim with the carrier immediately thereafter. AGS will give all reasonable assistance in tracing shortages and filing claims.

AGS will not accept any unauthorized non-defective returns, unless due to the fault of AGS. All non-defective product returns will be subject to a minimum 30% handling charge, or will be returned to the customer at their expense.

Credit will not be issued for goods returned without prior authorization. Return requests must be made to the address shown above and must include an itemized list of products to be returned, the reasons for return, and the date and number of the original invoice. Production identification must be intact.

Product weights and dimensions are subject to variation within reasonable tolerances. All items are subject to design improvement and change.

 

 Australian Gas Springs - LiftEasy Products

Address:  29 Tower Court    Noble Park    Victoria 3174    Australia